Power requirements, Site location, Power requirements -2 – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 26: Site location -2, Figure 1-1, Powervault 56f switch front view -2

Advertising
background image

1-2

Installation and Troubleshooting Guide

)$.  

Switch power connection is by way of a switched connector on the switch’s front right
side, as shown in Figure 1-1. The switch power requirements are as follows:



Properly wired, grounded outlet



Input voltage: 85–265 volts alternating current (VAC)



Total power: Up to 155 watts (see Appendix A, “Specifications” in the User’s
Guide
)



Input line frequency: 47 to 63 hertz (Hz)

The switch has an autoranging power supply that automatically accepts voltages
within its ranges.

     

NOTE: The switch meets International Electronic Commission (IEC) 801-5 surge volt-
age requirements; however, there is no other provision for surge protection built into
the switch’s power supplies. An installation should include normal provisions to
ensure clean power.

/ 

The switch should be installed in a secure or limited access site to control unautho-
rized access to the switch’s cabling and power connections.

NOTE: Do not block the front or back air vents. The switch must have clear access to
ambient air for cooling.

power supply 1

power supply 2