Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 154

Advertising
background image

A-18

Installation and Troubleshooting Guide

DIAG-POST_SKIPPED

(T
[switch initialization]

POST is skipped; its message
recommended that POST be
executed

Information only

None required

DIAG-REGERR

(T;5
[portRegTest, sramRetention-
Test]

Data read from ASIC register or
ASIC SRAM did not match data
previously written into same
location

ASIC failure

Replace main-
board assembly

DIAG-REGERR_UNRST

(T;5
[portRegTest, sramRetention-
Test]

Port failed to reset

ASIC failure

Replace main-
board assembly

DIAG-STATS

(T!!!5-

-!
[portLoopbackTest, crossPort-
Test]

Port counter value did not
match the number of frames
actually transmitted. Possible
counters reporting:
FramesTx: Number of frames
transmitted
FramesRx: Number of frames
received
Cl3FrmRx: Number of Class3
frames received

ASIC, GBIC mod-
ule or fiber cable
failure

Replace main-
board assembly,
GBIC module or
fiber cable

DIAG-TIMEOUT

(T!)5-)5- )
[portLoopbackTest, crossPort-
Test, centralMemoryTest]

For portLoopbackTest and
crossPortTest:
Port failed to receive frame
within timeout period
For centralMemoryTest:
Port failed to detect an inter-
rupt within the timeout period

ASIC, GBIC mod-
ule or fiber cable
failure

Replace main-
board assembly,
GBIC module or
fiber cable

DIAG-XMIT

(T!!75!75-75

- 7
[portLoopbackTest, crossPort-
Test, spinSilk, camTest]

Port failed to transmit frame

ASIC failure

Replace main-
board assembly

CONFIG CORRUPT

The switch configuration infor-
mation has become irrevoca-
bly corrupted

OS error

Contact customer
support

CONFIG OVERFLOW

The switch configuration infor-
mation has grown too large to
be saved or has an invalid size

OS error

Contact customer
support

CONFIG VERSION

The switch has encountered an
unrecognized version of the
switch configuration

OS error

Contact customer
support