Advanced Feature:

Rotated Ref. Line

Dialog for the definition of a rotated Reference line:

Enter the Line offset to define the starting point of the
reference line (1st Ref. Point).

Enter the rotation angle

α

αα

αα

.

F1

F1

F1

F1

F1

CONT

F2

F2

F2

F2

F2

DIST

To measure a distance and trigger the calculation of the
setting out elements in relation to the new reference line and
it's starting point.

Configuration:
Line /

α

= ON

REFLN\ Define Reference Line

1st BasePt :

1

2nd BasePt :

2

Offset

:

5.000 m

Line

:

1.500 m

Angle

α

αα

αα

:

15°00'00''

CONT

NEW-L

MC

REFLN\

Ref Line Results

Point Id

:

3

∆∆∆∆∆

Offset

:

1.230 m

∆∆∆∆∆

Line

:

2.463 m

∆∆∆∆∆

Ht

:

0.235 m

Elevation :

100.500 m

ALL

DIST

REC CONT

MC

1

100pr21

1st Base Pt.

Line +

α

Ref. Line

Offset +

Line +

2nd Base Pt.

Baseline

1st Ref.
Point

Offset +