2-1 Installation and Connection to Sensor Amplifiers

2-3

2

Connec

ti

on and

Conf

ig

u

ration

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -

Mounting on a DIN rail

1

Align the claw on the bottom of the amplifier with the DIN rail. While push-
ing the amplifier in the direction of arrow (1), press down in the direction
of arrow (2).

2

To remove the DL-DN1, raise the main unit in the direction of arrow (3)
while pushing it the direction of arrow (1).

Procedures for connecting to sensor amplifiers

The DeviceNet compatible communication unit DL-DN1 must be connected to sensor
amplifiers before it can function.
The connecting procedure varies with the mounting type of the sensor amplifiers to be
connected.

For the instructions on connecting additional sensor amplifiers, refer
to the instruction manual of the sensors amplifiers.

Connecting to sensor amplifiers (DIN rail mounting type)

1

Remove the expansion protective cover from the sensor amplifier to be
connected.

Installation and Connection to Sensor Amplifiers

(1)

(2)

(3)

Make sure that the power to the sensor amplifier is off before starting to
connect the DeviceNet compatible communication unit, DL-DN1. Per-
forming the procedure with the power on may damage the DL-DN1.

NOTICE

Point

Sensor amplifier

Expansion protective cover