3-3 Explicit Messaging

3-31

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -

Nx10+4

64

Group-4 entry count

R

26

65

Reserved

66

Range setting

R/W

0

0: NEAR
1: FAR
2: Ib

67 to

68

Reserved

69

Averaging

R/W

5

0:

1 time

1:

2 times

2:

4 times

3:

8 times

4:

16 times

5:

64 times

6:

256 times

7: 1024 times
8: 4096 times
9: 16384 times

6A

Output mode

R/W

0

0: N.O.
1: N.C.

6B

Reserved

6C

Hold function setting

R/W

0

0: Sample hold
1: Peak hold
2: Bottom hold
3: Absolute value hold
4: Auto peak hold
5: Auto bottom hold
6: Auto absolute value hold

6D

Reserved

6E

Timing input setting

R/W

0

0: Level
1: Edge

6F to

70

Reserved

71

Hysteresis

R/W

0.100 0 to 99.999

72

Analog output scaling

*14

R/W

0

0: Initial state
1: Free range

73

Analog output upper limit

*14

R/W

10.000 -99.999 to 99.999

74

Analog output lower limit

*14

R/W

-10.000 -99.999 to 99.999

75

External input setting

*15

R/W

0

0: Initial state
1: User setting

76

External input 1

*15

R/W

0

0: Zero shift input
1: Bank A input
2: Bank B input
3: Not use

77

External input 2

*15

R/W

0

0: Reset input
1: Bank A input
2: Bank B input
3: Not use

78

External input 3

*15

R/W

0

0: Timing input
1: Bank A input
2: Bank B input
3: Not use

79

External input 4

*15

R/W

4

0: Bank A input
1: Bank B input
2: Not used

7A

Bank switching method

R/W

0

0: Button
1: External input

7B

Reserved

7C

Save zero-shift state

R/W

0

0: OFF
1: ON

7D

Reserved

InstID
(DEC)

AttrID

(HEX)

Name

Description Attribute

Default

value

Parameter range