3-2 I/O Communication

3-7

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -

The device map varies depending on the operating mode of the DL-DN1.
Access each device in a manner suitable for the selected operating mode.

"Status" (page 3-7)

"Output" (page 3-8)

"Comparator value (P.V. value)" (page 3-10)

"External input" (page 3-11)

"Changing a BANK" (page 3-12)

"Rewrite setting value" (page 3-13)

Status

IN area

n: The first device number assigned to the DL-DN1

Status details

Device Maps

Device

(DEC)

Name

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit 15

Bit 14

Bit 13

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

n

Status

Reserved

Reserved

Reserved

Error ID

number

(MSB)

Error ID

number

Error ID

number

Error ID

number

Error ID

number

(LSB)

Error

status

Warning

status

Sensor

ready

Error code

(MSB)

Error code Error code Error code

Error code

(LSB)

Name

Description

Reading range

Error status

An error occurred with the DL-DN1 or sensor amplifier, or the
DL-DN1 is not communicating properly with the sensor amplifier.
If an error exists, the error ID number and error code are stored.

0: No Error
1: Error

Sensor ready

The sensor amplifier has started and is ready.

0: Starting
1: Ready

Error ID number

The error ID number is stored in the range of bit 0 (LSB) to bit 4
(MSB).

"Error information list"

(page 3-8)

Error code

The error code is stored in the range of bit 8 (LSB) to bit 12
(MSB).