- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -

2-2 Installation and Connection to Sensor Amplifiers

2-4

2

C

onn
ec

tion

and

C

onf

ig

ur

at

ion

„

Connecting the DL-EP1 to sensor amplifiers

The EtherNet/IP Compatible Network Unit DL-EP1 must be connected to sensor

amplifiers before it can function.

For the instructions on connecting additional sensor amplifiers, refer to the
instruction manual of each sensor amplifier.

1

Remove the expansion protective cover from the sensor amplifier to be

connected.

2

Mount the EtherNet/IP Compatible Network Unit DL-EP1, on the DIN rail

and connect it to the sensor amplifier.

Insert the EtherNet I/P Compatible Network Unit DL-EP1 to the sensor amplifier

connector so as not to leave space between them.

Make sure that the sensor amplifiers are turned off before

connecting the EtherNet/IP Compatible Network Unit DL-EP1.

Connecting the DL-EP1 to the sensor amplifiers when they are

turned on may damage the DL-EP1.

Make sure that the sensor amplifier connector (for DIN rail mount

type) is not askew on the side face of the EtherNet/IP Compatible

Network Unit DL-EP1 according to the figure shown below.

Connecting the DL-EP1 to the sensor amplifier with the connector

being askew may damage the DL-EP1.

NOTICE

Point

Sensor amplifier

Expansion protective cover

Sensor amplifier

EtherNet/IP Compatible Network Unit
DL-EP1

Connector

NOTICE

Sensor amplifier connector

EtherNet/IP Compatible Network Unit DL-EP1