4 message communication 3-37, Com m uni ca tin g w ith fd -m h se ries – KEYENCE DL-EP1 User Manual

Page 65

Advertising
background image

3-4 Message Communication

3-37

3

C

om
m

uni

ca

tin

g

w

ith FD

-M

H

Se
ries

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -

Group1

0329H

(809) to

032AH

(810)

(Reserved for system)

032BH

(811)

Bank

switching

status

Indicates the bank switching status.

Parameter range: 0 to 1

0: Bank A

1: Bank B

R

DINT

032CH

(812)

(Reserved for system)

032DH

(813)

Current

temperature

*5

Indicates the current temperature.

Parameter range: 0.0 to 999.9

R

DINT

032EH

(814)

Temperature

peak hold

value

*5

Indicates the temperature peak hold value.

Parameter range: 0.0 to 999.9

R

DINT

032FH

(815)

Temperature

peak hold

value

*5

Indicates the temperature bottom hold value.

Parameter range: 0.0 to 999.9

R

DINT

0330H

(816) to

0333H

(819)

(Reserved for system)

0334H

(820)

External input

status

Indicates the external input status.

Parameter range: 0 to 1

0:OFF

1:ON

R

DINT

0335H

(821)

(Reserved for system)

0336H

(822)

Temperature

sensor

connection

*6

Indicates the temperature sensor connection.

Parameter range: 0 to 1

0: Not connected

1: Connected

R

DINT

0337H

(823) to

033FH

(831)

(Reserved for system)

Group2

0340H

(832)

Group2 Entry

count

Indicates the group 2 entry count.

Parameter range: 8

R

DINT

0341H

(833)

Instantaneous

flow rate

setting value

1(P1)

*7

Indicates the instantaneous flow rate setting

value 1 (P1).

Parameter range:

FD-MH10A: 0.00 to 30.00 (initial value: 3.00)

FD-MH50A: 0.0 to 100.0 (initial value: 15.0)

FD-MH100A: 0.0 to 200.0 (initial value: 30.0)

FD-MH500A: 0.0 to 999.9 (initial value: 100.0)

R/W

DINT

0342H

(834)

Instantaneous

flow rate

setting value

2(P1)

*7

Indicates the instantaneous flow rate setting

value 2 (P2).

Parameter range:

FD-MH10A: 0.00 to 30.00 (initial value: 10.00)

FD-MH50A: 0.0 to 100.0 (initial value: 50.0)

FD-MH100A: 0.0 to 200.0 (initial value: 100.0)

FD-MH500A: 0.0 to 999.9 (initial value: 200.0)

R/W

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising