4 message communication 3-40 – KEYENCE DL-EP1 User Manual

Page 68

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -

3-4 Message Communication

3-40

3

C

om
m

uni

ca

tin

g

w

ith FD

-M

H

Se
ries

Group4

0388H

(904)

Integrated

flow rate unit

Indicates the integrated flow rate unit.

Parameter range: 0 to 6 (initial value: 2)

FD-MH10A: 0 to 4

FD-MH50A: 1 to 5

FD-MH100A: 1 to 5

FD-MH500A: 2 to 6

Parameter list

0:0.01

1:0.1

2:1

3:10

4:100

5:1000

6:10000

R/W

DINT

0389H

(905) to

038CH

(908)

(Reserved for system)

038DH

(909)

N.O./N.C.

Indicates N.O./N.C.

Bit 0: Output 1 (0:N.O./1:N.C.) (initial value: 0)

Bit 1: Output 2 (0:N.O./1:N.C.) (initial value: 0)

Bit 2: Output 3 (0:N.O./1:N.C.) (initial value: 0)

R/W

DWORD

038EH

(910)

Display mode

Indicates display mode.

Parameter range: 0 to 1

0:Std

1:rESo

Initial value:

FD-MH10A/FD-MH500A:0

FD-MH50A/FD-MH100A:1

R/W

DINT

038FH

(911)

Hysteresis

*7

Indicates hysteresis.

Parameter range:

FD-MH10A: 0.00 to 9.99 (initial value: 0.10)

FD-MH50A: 0.0 to 49.9 (initial value: 0.5)

FD-MH100A: 0.0 to 99.9 (initial value: 1.0)

FD-MH500A: 0.0 to 499.9 (initial value: 5.0)

R/W

DINT

0390H

(912)

Bank

switching

function

Indicates the bank switching function.

Parameter range: 0 to 1

0: OFF (initial value)

1:ON

R/W

DINT

0391H

(913)

(Reserved for system)

0392H

(914)

Flow zero

function

Indicates the flow zero function.

Parameter range: 0 to 1

0: OFF (initial value)

1:ON

R/W

DINT

0393H

(915)

(Reserved for system)

0394H

(916)

Different

frequency

mode

Indicates different frequency mode.

Parameter range: 0 to 1

0: Standard (initial value)

1: Different frequency mode

R/W

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising