4 message communication 3-33 – KEYENCE DL-EP1 User Manual

Page 61

Advertising
background image

3-4 Message Communication

3-33

3

C

om
m

uni

ca

tin

g

w

ith FD

-M

H

Se
ries

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -

Attributes

Instance

ID

Attribute

ID

Name

Description

Attribute

Data

Type

00H

64H

(100)

Status

Indicates the status of this unit and connected

sensor amplifier.

bit0: DL-EP1 Error Status

Bit 1 to bit 13: Reserved for system

bit14: Warning Status

bit15: Error Status

R

WORD

65H

(101)

Sensor Error

Status

Indicates the error status of the connected

sensor amplifiers. If an error occurs, the bit of the

corresponding ID number of amplifier is turned

to ON.

Bit 0 to bit 9: ID number 1 to ID number 10

Bit10 to bit 15: Reserved for system

R

WORD

66H

(102)

Warning

Status

(Unassigned)

R

WORD

67H

(103)

Reserved for system

68H

(104)

Current

Value 0

Property

Indicates the status of current value 0 of each

amplifier. If the current value 0 is “Over Range",

“Under Range", or "Invalid", the bit

corresponding to the ID number is turned ON.

Bit 0 to bit 9: ID number 1 to ID number 10

Bit10 to bit 15: Reserved for system

R

WORD

69H

(105)

Current

Value 1

Property

(Unassigned)

R

WORD

6AH

(106) to

6BH

(107)

Reserved for system

6CH

(108)

Error ID

Number

Indicates the ID number of the unit having error.

Parameter range: 0 to 10 (initial value: 0)

R

UINT

6DH

(109)

Error Code

Indicates the error code that is happening.

Parameter range: 0 to 65535 (initial value: 0)

R

UINT

6EH

(110)

Warning ID

Number

(Unassigned)

R

UINT

6FH

(111)

Warning

Code

(Unassigned)

R

UINT

70H

(112) to

73H

(115)

Reserved for system

74H

(116)

Output1

Indicates the output 1 status of each sensor

amplifier. When output 1 is output, the bit

corresponding to the ID number of the sensor

amplifier is turned ON.

Bit 0 to bit 9: ID number 1 to ID number 10

Bit10 to bit 15: Reserved for system

R

WORD

Advertising