KEYENCE DL-RS1A/IL User Manual

Page 13

Advertising
background image

11

Parameters of Commands and Responses

„ Data numbers

Specify the data number using three digits (ASCII characters).

z

Read-only data

The following table lists the types of data that can only be read from the IL Series sensor amplifiers.

Writing read-only data results in a communication error (error number: 22).

*1

In the Data format column, "±" indicates that the value can be either "+" or "-" and "*" signifies a
number from "0 to 9". The values shown in parentheses apply for the IL-300/600, and the values
shown in double parentheses apply for the IL-2000.

*2

R: Indicates that the data type can only be read from the sensor amplifiers.

Data

number

Data name

Data

type

*1

Number of
characters

Attribute

*2

Readout range

*15

033

Sensor amplifier error

*3

*****

5

R

0 to 65535

036

Judgment output/Alarm output

*4

**

2

R

0 to 15

037

Judgment value (P.V. value)

*5

±**.***

(±***.**)

((±****.*))

7

R

-99.999 to +99.999
(-999.99 to +999.99)
((-9999.9 to +9999.9))

038

Internal measurement value (R.V. value)

*5

7

R

039

Peak hold value during hold period

*5

7

R

040

Bottom hold value during hold period

*5

7

R

041

Calculation value (CALC value)

*5 *6

7

R

042

Analog output value

*6

±*.***

or

**.**

Voltage output

6

Current output

5

5

Voltage output
-5.000 to +5.000

*7

Current output
04.00 to 20.00

*7

043

Bank status

*

1

R

0 to 3

044

Timing status

*

1

R

0: During sampling
1: Not during sampling

050

Laser emission stop state

*

1

R

0: Laser emitting
1: Laser stopped

051

Abnormal setting

*8

*

1

R

0: Normal setting
1: Abnormal setting

052

External input status

**

2

R

0 to 15

*14

053

EEPROM write result

*12

*

1

R

0: Executing
1: Normal termination
2: Execution impossible

054

Zero shift/Zero shift reset result

*9

*

1

R

0: Executing
1: Normal termination
2: Execution impossible

055

Reset request result

*

1

R

0: Executing
1: Normal termination
2: Execution impossible

056

Current system parameters

*13

**

2

R

0 to 15

060

Tolerance tuning/2 point tuning result

*10

*

1

R

0: Executing
1: Normal termination
2: Execution impossible

061

Calibration result

*11

*

1

R

0: Executing
1: Normal termination
2: Execution impossible

193

Product code

****

4

R

Main unit: 4022
Exp. units: 4023

195

Connected sensor head

****

4

R

0000: No connection
0001: IL-030
0002: IL-065
0003: IL-100
0004: IL-300
0005: IL-600
0106: IL-S025
0107: IL-S065
0208: IL-S100
0311: IL-2000

Point

Parameters of Commands and Responses

*3

You can read data number "033" to check the error status of the sensor amplifiers. Convert the
five digit number (ASCII characters) read from the sensor amplifiers to a binary number and
check the ON/OFF state of each bit to check the error.

For information on each error, refer to "IL Series User's Manual"

When the data read from a sensor amplifier is "00257":

"257" converted to binary number is "0000 0001 0000 0001".

Therefore, this data indicates that an "Overcurrent error" and a "Model mismatch
error" have simultaneously occurred at the sensor amplifier from which it was read.

If no error has occurred at the sensor amplifier, the data "00000" is returned.

*4

You can read data number "036" to check the judgment output status.
Convert the two digit number (ASCII characters) read from the sensor amplifiers to a binary
number and check the ON/OFF state of each bit to check the judgment output status.

When the data read from a sensor amplifier is "05":

"05" converted to binary number is "0101".

During N.O.

Bit

Sensor amplifier error details

0

Overcurrent error

1

EEPROM error

2

Sensor head error

3

Unused

4

Unused

5

Unused

6

Unused

7

Spot light laser error

8

Incompatable model error

9

Unused

10

Unused

11

Amplifier communication error

12

Number of units error

13

Calculation error

Bit

Judgment output

N.O.

N.C

0

0: HIGH Judgment output OFF,

1: HIGH judgment output ON

0: HIGH Judgment output ON,

1: HIGH judgment output OFF

1

0: LOW Judgment output OFF,

1: LOW Judgment output ON

0: LOW Judgment output ON,

1: LOW Judgment output OFF

2

0: GO Judgment output OFF,

1: GO Judgment output ON

0: GO Judgment output ON,

1: GO Judgment output OFF

3

0: Alarm output ON,

1: Alarm output OFF

0: Alarm output ON,

1: Alarm output OFF

Reference

Bit 8: Model mismatch error

Bit 0: Overcurrent error

Reference

Bit 3: Alarm output ON

Bit 0: HIGH judgment output ON

Bit 2: GO judgment output ON

Bit 1: LOW judgment output OFF

Advertising