Connecting the Unit to Sensor Amplifiers

„ Connecting the unit to panel mount sensor amplifiers

1

Connect DL-RS1A to the sensor amplifiers using the optional expansion cable (OP-35361).

2

Remove the sensor amplifier connector with pliers (for DIN rail mounting when using with panel

mounted sensor amplifiers) from DL-RS1A unit and install the expansion connector cover

supplied with the unit.

• Make sure you securely connect the expansion cable while the unit is turned

off. Turning the power on when the cable is not inserted straight or firmly

connected may damage the unit.

• Removing or inserting the cable while the power is on may damage the unit.

Remove the
protection sticker

Expansion cable (cable length: 300 mm)
(OP-35361)

NOTICE

Sensor amplifier connector
(for DIN rail mounting type)

Expansion connector cover

Connecting the Unit to External Devices

Communication Terminal Block

You can connect external devices such as a PC or PLC to the communication terminal block of
DL-RS1A via the communication cables.

„ Terminal connection

*

Recommended communication cable
KPEV-SP(1P) wire with balanced type twisted shield (strand wire)
Nominal cross-section area 0.16mm

2

(AWG25) min.

A terminal cover is attached to the terminal block.
The terminal cover must be placed over the terminal block when you finish connecting the cables.

The terminals for SG (Nos. 1, 4, and 5) are used in common with the blue wire of the sensor amplifier

main unit.

z

Crimp-type terminal

Use the Y or round terminal for wiring to the I/O terminal.
Use the Y or round terminal with the following dimensions.

Y terminal

Round terminal

SG

RD

SD

SG

SG

DRQ

Communication cable

To external device

KPEV-SP(1P) wire with balanced
type twisted shield (strand wire)

Terminal No.

Terminal

Description

1

SG

Connects to the shielded wire of the communication cable.
The terminals for SG (Nos. 1, 4, and 5) are internally short-circuited.

2

RD (input)

Connects to the SD terminal of an external device via a communication cable.

3

SD (output) Connects to the RD terminal of an external device via a communication cable.

4

SG

The terminals for SG (Nos. 1, 4, and 5) are internally short-circuited.

5

SG

The terminals for SG (Nos. 1, 4, and 5) are internally short-circuited.

6

DRQ (input)

When there is a short-circuit between DRQ and SG, the sensor amplifier data is
transmitted even without a command from the external device.

Point

Reference

Excerpted from dimensions of the Y terminal areas
B: Outer size of Y area
d: Width of inner Y area

(joint area with screw)

Applicable dimension
B: 6mm max.
d: 3.2mm min.

Excerpted from dimensions of the round terminal areas
B: Outer diameter
d: Inner diameter

(joint area with screw)

Applicable dimension
B: 6mm max.
d: 3.2mm min.