KEYENCE DL-RS1A/IL User Manual

Page 16

Advertising
background image

14

Parameters of Commands and Responses

141

Hysteresis

**.***

(***.**)

((****.*))

6

R/W

0 to 99.999
(0 to 999.99)
((0 to 9999.9))

0.000 (0.00)

((0.0))

142

Analog output scaling

*5

*

1

R/W

0: Initial state
1: Free range
2: Bank

0

143

Analog output - upper limit value

*5 *10

±**.***

(±***.**)
((±****.*))

7

R/W

-99.999 to +99.999
(-999.99 to +999.99)
((-9999.9 to +9999.9))

10.000 (100.00)

((1000.0))

144

Analog output - lower limit value

*5 *10

7

R/W

-10.000 (-100.00)

((-1000.0))

145

External input

*11

*

1

R/W

0: Initial state
1: User setting

0

146

External input 1

*11

*

1

R/W

0: Zero shift input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not used

0

147

External input 2

*11

*

1

R/W

0: Reset input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not used

0

148

External input 3

*11

*

1

R/W

"0: Timing input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not used

0

149

External input 4

*11

*

1

R/W

0: Not used
1: Bank A input
2: Bank B input
3: Laser emission stop input

0

150

Bank switching method

*

1

R/W

0: Button
1: External input

0

152

Zero shift value memory function

*

1

R/W

0: OFF
1: ON

0

153

Mutual interference prevention function

*5

*

1

R/W

0: Interference prevention OFF
1: Interference prevention ON

0

154

Display columns

*

1

R/W

0: Initial settings
2: 0.001
3: 0.01
4: 0.1
5: 1

0

155

Power saving function

*

1

R/W

0: OFF
1: Half
2: All

0

156

Head display mode

*

1

R/W

0: Initial state
1: OK/NG display
2: OFF

0

157

Display color

*

1

R/W

0: GO Green
1: GO Red
2: Always red

0

158

Timer duration of diff. count filter

****

4

R/W

2 to 9999

10

159

Cutoff frequency of high-pass filter

*

1

R/W

0: 0.1Hz
1: 0.2Hz
2: 0.5Hz
3: 1Hz
4: 2Hz
5: 5Hz
6: 10Hz
7: 20Hz
8: 50Hz
9: 100Hz

3

161

Alarm setting

*

1

R/W

0: Initial state
1: Clamp
2: User setting

0

162

Alarm count

****

4

R/W

2 to 1000

7

Data

number

Data name

Data

type

*1

Number of
characters

Attribute

*2

Readout range

*14

Initial

value

*14

Parameters of Commands and Responses

*1

In the Data format column, "±" indicates that the value can be either "+" or "-" and "*" signifies a
number from "0 to 9". The values shown in parentheses apply for the IL-300/600, and the values
shown in double parentheses apply for the IL-2000.

*2

Indicates that the data can only be read from (R), can only be written to (W), or can be both
read from and written to (R/W) the sensor amplifiers.

*3

The request is executed only when the data is changed from 0 to 1. To re-execute the request,
first change the setting to 0, then change it to 1. Otherwise, the request is not executed. If the
sensor amplifier is turned off after a zero shift operation, the system returns to the status which
existed prior to the zero shift. In order to maintain the shift condition even after a power off, the
"zero shift status save" function must be set to ON.

*4

The system parameter means the polarity of judgment output and the setting for analog output.

*5

Writing data to the expansion unit results in a communication error (error number: 22).

*6

Enabled when "Analog output scaling" is set to "Bank".

*7

Enabled when "Bank switching method" is set to "Button".

*8

Only when data 0 is written and the external input is OFF for wiring, it operates as OFF.

*9

Specify the system parameter set when data number 06 (System parameter set request) is
written. Convert the two digit number (ASCII characters) to a binary number and check the ON/
OFF state of each bit to specify the system parameter.

When the specified data is "006":
"6" converted to binary number is "0110".

Therefore, the setting of the amplifier to which the data is written is "NPN output" and "Analog
output 1 to 5 V".

*10 Enabled when "Analog output scaling" is set to "Free range".

*11 To reflect the setting written for the data number 146 to 149 to the sensor amplifier, write 1 (user

setting) for the data number 145 or set the external input setting to "User setting" with the button
operation on the sensor amplifier.

*12 Correction is not possible if the setting is changed between the 1st and 2nd execution requests.

If a correction is desired, avoid making setting changes during the correction operation.

*13 Execution requests are enabled only if the "Calibration function" is set as "User setting".

Moreover, these requests can be executed only if the "Calibration function" is set as "Calculated
two-point calibration" and "Calculated three-point calibration".

*14 The values shown in parentheses apply for the IL-300/600, and the values shown in double

parentheses apply for the IL-2000.

Bit

Initial setting details

0

0: NPN output, 1: PNP output

3, 2, 1

000: Analog output OFF
001: 0 to 5 V
010: -5 to +5 V
011: 1 to 5 V
100: 4 to 20 mA

Reference

Bit 3, 2, 1: 1 to 5 V

Bit 0: NPN output