Connecting the Unit to External Devices

„ Connection wiring

Refer to the connection wiring diagram shown below when connecting DL-RS1A to an external
device such as a PC.

• The length of the communication cable must not exceed 15 m.

• Connect the shield wire of the communication cable to the SG terminal of the external device.

• Make sure that the shield wire does not touch other signal wires or the other terminals on

the terminal block.

„ Optional cable

An optional cable shown below is used to connect to an external device such as a PC that has
a D-sub 9-pin I/O connector.

Part number: OP-81283

Pin layout for D-sub 9-pin connector

*1

Pin numbers 4 and 6 are connected inside the connector.

*2

Pin numbers 7 and 8 are connected inside the connector.

*3

Two cables (black and black/white) are connected to the pin number 5.

SD

RD

DR

ER

RS

CS

SG

2

1

3

4

5

6

RD

SG

SD

SG

SG

DRQ

DL-RS1A

External device

(D-sub 9-pin)

Shield

Point

Pin No.

Cable color

1

-

2

Red/white

3

Red

4

*1

-

5

Black, black/white

*3

6

*1

-

7

*2

-

8

*2

-

9

-

33.2

25

16

5000

39.5

1

50

φ7.1

Front

5

9

6

1

Connecting the Unit to External Devices

Sample wiring

*1

Insulate either the black or black/white cable that is not used.

*2

Connect the shield wire to the SG terminal of DL-RS1A. (Shield wire is connected to the
connector casing.)

The green and green/white-striped wires are not connected to any of the connector pins.

„ Input circuit diagram

*

The terminals for SG (Nos. 1, 4, and 5) are connected internally with the blue wire of the sensor
amplifier main unit.

2

3

4

5

6

7

RD

Red/White

Red

SD

DR

SG

ER

RS

8

CS

2

1

3

4

5

6

RD

SG

SD

SG

SG

DRQ

Black, Black/White*

1

DL-RS1A

(Communication terminal block)

External device

(D-sub 9-pin)

Shield

*

2

Reference

Main cir

cuit

(Short-circuit current: 1 mA max.)

6 (DRQ)

+5V

1,4,5 (SG)