4 command parameter list, Co mm u ni c a ting w ith t he fd -s s er ie s – KEYENCE DL-CL1 User Manual

Page 55

Advertising
background image

3-4 Command Parameter List

3-27

3

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-S

s

er

ie

s

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -

00

nn25

Instantaneous flow
rate value

*3

R

FD-SS02

-

-400.0 to +400.0

FD-SF1(S)

-2000 to +2000

FD-SF1(F)

-400.0 to +400.0

FD-SS2(S)

-4000 to +4000

FD-SS2(F)

-400.0 to +400.0

FD-SF8(S)

-16.00 to +16.00

FD-SF8(F)

-4000 to +4000

FD-SS20(S)

-40.00 to +40.00

FD-SS20(F)

-4000 to +4000

nn26

Integrated flow
quantity (for
Version A)

*4

R

FD-SS02

-

-21474836.48 to +21474836.47

FD-SF1(S)

-214748364.8 to +214748364.7

FD-SF1(F)

-21474836.48 to +21474836.47

FD-SS2(S)

-214748364.8 to +214748364.7

FD-SS2(F)

-21474836.48 to +21474836.47

FD-SF8(S)

-2147483.648 to +2147483.647

FD-SF8(F)

-214748364.8 to +214748364.7

FD-SS20(S)

-2147483.648 to +2147483.647

FD-SS20(F)

-214748364.8 to +214748364.7

nn27

Instantaneous flow
rate (peak hold
value)

*3

R

FD-SS02

-

-400.0 to +400.0

FD-SF1(S)

-2000 to +2000

FD-SF1(F)

-400.0 to +400.0

FD-SS2(S)

-4000 to +4000

FD-SS2(F)

-400.0 to +400.0

FD-SF8(S)

-16.00 to +16.00

FD-SF8(F)

-4000 to +4000

FD-SS20(S)

-40.00 to +40.00

FD-SS20(F)

-4000 to +4000

nn28

Instantaneous flow
rate (bottom hold
value)

*3

R

FD-SS02

-

-400.0 to +400.0

FD-SF1(S)

-2000 to +2000

FD-SF1(F)

-400.0 to +400.0

FD-SS2(S)

-4000 to +4000

FD-SS2(F)

-400.0 to +400.0

FD-SF8(S)

-16.00 to +16.00

FD-SF8(F)

-4000 to +4000

FD-SS20(S)

-40.00 to +40.00

FD-SS20(F)

-4000 to +4000

nn29 to

nn2A

System reserved

nn2B

Bank switching
state

R

-

-

0: Bank A
1: Bank B

nn2C

System reserved

nn2D

Current
temperature

*5

R

-

-

+000.0 to +099.9

nn2E

Temperature
(peak hold value)

*5

R

-

-

+000.0 to +099.9

nn2F

Temperature
(bottom hold
value)

*5

R

-

-

+000.0 to +099.9

nn30

Instantaneous
density

R

-

-

00.00 to 99.99

Data

category

(HEX)

Data

number

(HEX)

Name

Description

Attribute

Sensor head

Default

value

Parameter range

Advertising