4 command parameter list, Co mm u ni c a ting w ith t he fd -s s er ie s – KEYENCE DL-CL1 User Manual

Page 56

Advertising
background image

3-4 Command Parameter List

3-28

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-S

s

er

ie

s

3

00

nn31

Integrated flow
quantity (except
for version A)

R

FD-SS02

-

-21474836.4 to +21474836.4

FD-SF1(S)

-214748364 to +214748364

FD-SF1(F)

-21474836.4 to +21474836.4

FD-SS2(S)

-214748364 to +214748364

FD-SS2(F)

-21474836.4 to +21474836.4

FD-SF8(S)

-2147483.64 to +2147483.64

FD-SF8(F)

-21474836.4 to +21474836.4

FD-SS20(S)

-2147483.64 to +2147483.64

FD-SS20(F)

-21474836.4 to +21474836.4

nn32 to

nn33

System reserved

nn34

External Input
Status

R

-

-

0: OFF
1: ON

nn35

System reserved

nn36

Shift system
processing result

R

-

0

0: Successfully completed.
1: Abnormally terminated

nn37 to

nn3F

System reserved

nn40

Group-2 entry
count

R

-

10

nn41

Instantaneous
flow rate setting 1
(P1)

*3

R/W

FD-SS02

030.0

000.0 to 400.0

FD-SF1(S)

0300

0000 to 2000

FD-SF1(F)

030.0

000.0 to 400.0

FD-SS2(S)

0300

0000 to 4000

FD-SS2(F)

030.0

000.0 to 400.0

FD-SF8(S)

02.00

00.00 to 16.00

FD-SF8(F)

0300

0000 to 4000

FD-SS20(S)

03.00

00.00 to 40.00

FD-SS20(F)

0300

0000 to 4000

nn42

Instantaneous
flow rate setting 2
(P2)

*3

R/W

FD-SS02

100.0

000.0 to 400.0

FD-SF1(S)

0500

0000 to 2000

FD-SF1(F)

100.0

000.0 to 400.0

FD-SS2(S)

1000

0000 to 4000

FD-SS2(F)

100.0

000.0 to 400.0

FD-SF8(S)

04.00

00.00 to 16.00

FD-SF8(F)

1000

0000 to 4000

FD-SS20(S)

10.00

00.00 to 40.00

FD-SS20(F)

1000

0000 to 4000

nn43

Temperature
upper limit setting

*6

R/W

SUS type

80.0

000.1 to 100.0

PFA type

60.0

nn44

Temperature lower
limit setting

*7

R/W

-

10.0

000.0 to 099.9

nn45

Integrated flow
quantity setting 1

R/W

-

0150

0000 to 9999

nn46

Integrated flow
quantity setting 2

R/W

-

9999

0000 to 9999

Data

category

(HEX)

Data

number

(HEX)

Name

Description

Attribute

Sensor head

Default

value

Parameter range

Advertising