KEYENCE LS-Navigator User Manual

Page 30

Advertising
background image

4

LS-Navigator-M-NO4-E

4-4

4-2 Basic Procedures for Operation

3

Select the model of the controller
connected to the computer from the
following options.
LS-7000 Series, LS-7600/LS-7500 Series

Note

The model of the controller connected to the

computer must be the same as the model selected in

this window on LS-Navigator.

4

Select the method for reading the setting
contents from the following options.
Read controller settings, Read from file, Start
with defaults

When [Read controller settings] is

selected

After the [Communicating...] message appears,
the [Parameter update results] message is
displayed. Click on the [OK] button to display the
main window.

Note

When selecting [Read controller settings], click on

the [Communication Settings] button and change the

values in the [Communication settings] dialog so that

the values for the RS-232C communication

conditions on the software are the same as on the

controller. Click on the [Comm check] button to check

whether the RS-232C communication conditions are

the same on the controller and the computer.

For more details, see “Setting RS-232C
Communication Conditions” (Page 5-12) in this
manual.

When [Read from file] is selected
The [Open] dialog appears. Select the file to load
and click on the [Open] button to display the
main window.

For more details, see “Reading setting files”
(Page 5-3).

When [Start with defaults] is selected
The [Select the settings to display at startup]
window disappears and the main window is
displayed.

4

3

Advertising