Replacing an existing gbe interconnect switch, Replacing an existing gbe interconnect switch -3, 2 installing – Compaq ProLiant Interconnect Switch User Manual

Page 29: Interconnect switches -3

Advertising
background image

Setting Up and Installing the GbE Interconnect Switch

Compaq ProLiant BL p-Class GbE Interconnect Switch User Guide

2-3

COMPAQ CONFIDENTIAL Codename: Vanilla Part Number: 263680-001 Last Saved On: 4/23/02 9:57 AM

2. Slide the GbE Interconnect Switch into the right communication bay in the front side of

the ProLiant BL p-Class server blade enclosure (1).

3. Lock the ejector lever (2).

1

2

Figure 2-2: Installing the GbE Interconnect Switches

4. Repeat steps 2 and 3 for the second GbE Interconnect Switch in the left

communication bay.

IMPORTANT: Be sure that the interconnect modules are fully seated. The latch/handle will drop
into place when the module is firmly seated.

Replacing an Existing GbE Interconnect Switch

CAUTION: Removing an RJ-45 Patch Panel from a powered enclosure will result in the loss
of network communications between the server blade and the network infrastructure.

IMPORTANT: If you are replacing an existing GbE Interconnect Switch or upgrading from an RJ-45
Patch Panel, and have strict security requirements:

•

Do not cable the GbE Interconnect Switch until after configuration.

Or

•

Connect the GbE Interconnect Switch to the optional Diagnostic Station. The Diagnostic Station
enables you to power up, configure, and diagnose a ProLiant p-Class server blade or a ProLiant
p-Class GbE Interconnect Switch outside of the rack environment.

To replace an existing GbE Interconnect Switch:

1. If possible, save the configuration file to a TFTP server for later retrieval. Refer to the

“Saving Settings to a TFTP Server” section in Chapter 3 (console management interface)
and “Saving Settings to TFTP Server” in Chapter 4 (Web-based management interface).

2. On the front side of the ProLiant BL p-Class server blade, release the ejector lever for the

GbE Interconnect Switch.

3. Pull down on the ejector lever to unlock the GbE Interconnect Switch from the enclosure.

Advertising