3

INPUT

: AC 110 ~ 240V

OUTPUT : DC 12V 3A

This is a Door Lock Timer

Lengthen timing

Shorten timing

1

2

2

1

3

1

2

3

THE DESIGN

AdapTec consists of 2 main modules and a timer:

1

Power supply/power input
module.

2

Access control/power output

module.

3

Door lock timer.

POWER SUPPLY/POWER INPUT MODULE

1

This portion is to be connected to

power source with AC110~240V.
AC current will be supplied into
this side and a DC 12V 3A current
will be generated as output.

2

These two cables, -V and +V are

default and connected to the in-
ner part of AdapTec. Please do not
remove or change these cables.

ACCESS CONTROL/POWER OUTPUT MODULE

1

Connect push button here if siren

is installed during installation. A
press on the push button will turn
off siren when the siren is trig-
gered.

2

AdapTec may have broken and

needs to be repaired.

3

These are the power outputs from

AdapTec. Refer to the wiring dia-
grams in page 3, for details.

DOOR LOCK TIMER

User can adjust the timing for the EM Lock and Drop Bolt to close after opening using door

lock timer. Turn the timer using a screwdriver, turning clockwise will lengthen the time, turn-

ing anti-clockwise will shorten the time.

Note:

AdapTec can be connected to other devices, which are having the same power consump-

tion. Please seek FingerTec®’s advice through [email protected] before using AdapTec with
other FingerTec® models.