Wiring diagrams, Time attendance only, Rb g – FingerTec AdapTec AC User Manual

Page 6

Advertising
background image

6

R

Red

B

Blue

G

Green

AdapTec AC

Access Control/Power Output Module

Siren

Tamper

Siren Relay

12V

EM Accept Output Switch EXT.

Door

To

Battery

Accept

OK 12V MAX

0.5A Voltage

Input

I/P Exit

0 0

0 12V 0 12V C NC

12V 0

- +

NC2

COM2

NO2

NC1

COM1

NO1

BUT

GND

SEN

485B

485A

GND

232T

232R

GND

WD1

WD0

RJ45-1

RJ45-2

RJ45-3

RJ45-6

BELL+

BELL-

BEEP

GLED

RLED

INWD0

INWD1

GND

+12V

L

N

E

-V

+V

Power Supply/Power Input Module

AC110~240V

L - Live

N - Neutral

E - Earth

R

B

G

WIRING DIAGRAMS

R2/M2, i-Kiosk100, i-Kiosk100 Plus, Q2i and Kadex

TIME ATTENDANCE ONLY

STEP 1 •

Connection Points

STEP 2 •

Connect AdapTec AC to a Power Source

STEP 3 •

Now you can turn on the power source and using the system for

time attendance purpose only.

Advertising