Wiring diagrams, Face id 2, Time attendance only – FingerTec AdapTec AC User Manual

Page 9: Rb g

Advertising
background image

9

AdapTec AC

Access Control/Power Output Module

Siren

Tamper

Siren Relay

12V

EM Accept Output Switch EXT.

Door

To

Battery

Accept

OK 12V MAX

0.5A Voltage

Input

I/P Exit

0 0

0 12V 0 12V C NC

12V 0

- +

L

N

E

-V

+V

Power Supply/Power Input Module

AC110~240V

L - Live

N - Neutral

E - Earth

R

B

G

NO 2

COM 2

NC 2

SEN

GND

BUT

NO 1

COM 1

NC 1

485-

485+

GND

TXD

RXD

WD 0

WD 1

SGND

GND

+12V

DC 12V

Rechargeable

Backup

Battery

R

Red

B

Blue

G

Green

Connection
Points in
FingerTec®
Face ID2

WIRING DIAGRAMS

Face ID 2

TIME ATTENDANCE ONLY

STEP 1 •

Connection points

STEP 2 •

Connect AdapTec AC to a power source

STEP 3 •

Turn on the power to use FingerTec® Face ID 2 for time attend-

ance.