Measurement Scales

You can choose either English or metric scaling for the coordinates you digitize. Super L III
applies the required conversion factor before constructing a coordinate format for output.

The numbers appearing in coordinate formats depend on resolution. Table 12 shows how
the resolution settings affect the data in coordinate formats.

To set the measurement scale:

Tablet Configuration Utilities: Select a resolution in the “Resolution” column of Mode
Options.

GTCO Commands:

1. Send command IN for English or command MT for metric measurements.
2. Send command LR for 100 lpi/200 LPI/10 lpmm, command HR for 1000 lpi/40 lpmm

or command H1 for 2000 lpi/100 lpmm resolution.

Metric example: The distance between two points is 2032 counts in the 40 lpmm binary
format. Each count represents 0.025 mm (from Table 12). Then, 2032 counts x 0.025
mm/count = 50.8 mm.

Table 12: Measurement Scales