GTCO Surface-Lit AccuTab - Users Guide User Manual

Page 38

Advertising
background image

Surface-Lit AccuTab 38


Select Remote Request Mode

Code: RM

Read Current Coordinate

Code: hex 02 (Ctrl-B)

The Read Current Coordinate causes AccuTab to output a coordinate while it is in Remote
Request Mode. This command can be sent to the AccuTab only when it is digitizing and
only when Remote Request Mode has been selected by command RM. The Read Current
Coordinate command will be ignored if AccuTab is in Command Mode. Please note that
this command is not two ASCII characters. It is the one-byte-long STX character, CTRL-B
(hex 02). AccuTab responds to the Read Current Coordinate command by transmitting one
format.

Set Increment Value

Code: IV

In Line Incremental and Continuous Incremental modes, the AccuTab outputs a coordinate
when the transducer is moved beyond a certain incremental distance in either the X or Y
direction. The default increment is 0.01”. The Set Increment Value command allows the
user to select the distance which the transducer must move to initiate coordinate output.
It works as follows:

1. Enter Command Mode by sending a CTRL-A.
2. After receiving the > prompt, send IV and a <CR> (hex 0D).
3. The Controller will respond with a <.
4. After receiving the <, send a three-digit string ranging from 000 to 999. This string

represents an increment value of 0.000 to 0.999 inch.

5. When the Controller receives the last character it will respond with a > prompt and

await the next command.

Send Coordinates 0,0 When Transducer is Out of Active Area
No Output When Transducer is Out of Active Area

Code: OP
Code: IP

Certain situations require that the AccuTab be able to send a coordinate when the
transducer is out of the active area. Command OP permits coordinates to be sent under
this condition. Since valid coordinates are not available when the transducer is out of the
active area, coordinates 0,0 are substituted in the format. When this command has been
executed, digitizing modes operate normally, whether the transducer is in the active area
or not. Command IP returns AccuTab to the default condition, in which coordinates are
sent only when the transducer is in the active area.



Advertising