GTCO Surface-Lit AccuTab - Users Guide User Manual

Page 62

Advertising
background image

Surface-Lit AccuTab 62


Continuous Mode

In Continuous Mode, coordinates are sent continuously, at the specified output rate.
Output occurs only when the transducer is in the active area. Output occurs continuously,
whether or not a transducer button is pressed.

To select Continuous Mode:

Custom Configuration Menu:


GTCO Commands:

Select the “Cont” option under Mode; select
12, 50 or 100 under Rate.

Send command CN; to select a rate, send
command Rx (where x = 1-6), as shown in
Table 13.

Line Incremental Mode

In Line Incremental Mode, one coordinate is sent when the transducer is moved farther
than a preset increment and a transducer button is pressed. Default increment is 0.01”.
Output occurs only when the transducer is in the active area.

To select Line Incremental Mode:

Custom Configuration Menu:

GTCO Commands:

Select the “Line Incr” option under Mode.

Send command IC; to set a new increment
value, send command IV and at the prompt,
send three digits representing the new
increment in units of 0.001”.

Continuous Incremental Mode

In Continuous Incremental Mode, one coordinate is sent when the transducer is moved
farther than a preset increment or a transducer button is pressed or released. Default
increment is 0.01”. Output occurs only when the transducer is in the active area.

To select Continuous Incremental Mode:

Custom Configuration Menu

Select the “Cont Incr” option under Mode.