GTCO Surface-Lit AccuTab - Users Guide User Manual

Page 41

Advertising
background image

Surface-Lit AccuTab 41


and Y portions of each ASCII format will be six digits long.

If binary formats have been selected, the least significant bits represent 0.0005 inch or 0.01
millimeter, depending on whether English or metric scale has been selected.

Pushbutton Include
Pushbutton Exclude

Code: PI
Code: PE

Space Include
Space Exclude

Code: SI
Code: SE

Carriage Return Include
Carriage Return Exclude

Code: CI
Code: CE

Line Feed Include
Line Feed Exclude

Code: LI
Code: LE

These commands control the presence of the corresponding characters in ASCII formats.
Pushbutton codes and where they appear in coordinates are described in the Advanced
Programming Information
section. When included, the space is an additional character
separating the X and Y components of the coordinate data. When included, the LINE FEED
is an additional character following the <CR>.

Alarm, Status Indicator and Cursor Illumination Commands

Enable Alarm
Disable Alarm

Code: AE
Code: AD

These commands enable or disable the audible alarm. When enabled, a short tone will
sound when a transducer switch is pressed. When disabled, the alarm will not sound in
response to transducer switch presses, but it may be sounded by remote commands and
will be active during diagnostics and in the menu modes.

Sound Tone
Tone Pause

Code: T1
Code: T0

The Sound Tone command allows a remote device to sound the AccuTab’s audible alarm.
Tone Pause provides a pause between tones. Tones and pauses are in 0.25 second
intervals. Tone commands are not affected by the Disable Alarm command.