Format Selection Commands

ASCII Format Output

Code: AS

Command causes coordinates to be transmitted in ASCII. ASCII coordinates can be
modified by the Low/High/Highest Resolution, Pushbutton, Space, Carriage Return and Line
Feed commands and by menu settings.

Binary Format Output

Code: BI

Command causes coordinates to be transmitted in binary format. Binary coordinates can
be modified by the Low/High/Highest Resolution commands and by menu settings.

Low Resolution

Code: LR

Command modifies ASCII and binary formats. If ASCII formats have been selected, the Low
Resolution command causes the least significant digit to represent 0.01 inch or 0.1
millimeter, depending on whether English or metric scale has been selected. Both X and Y
portions of each ASCII format will be four digits long if in English scale or five digits long if in
metric scale.

If the binary format is selected, the least significant bits represent 0.005 inch or 0.1
millimeter, depending on whether English or metric scale has been selected.

High Resolution

Code: HR

Command modifies ASCII and binary formats. If ASCII formats have been selected, the
High Resolution command causes the least significant digits to represent 0.001 inch or
0.025 millimeter, depending on whether English or metric scale has been selected. Both X
and Y portions of each ASCII format will be six digits long.

If binary formats have been selected, the least significant bits represent 0.001 inch or 0.025
millimeter, depending on whether English or metric scale has been selected.

Highest Resolution

Code: H1

Command modifies ASCII and binary formats. If ASCII formats have been selected, the
Highest Resolution command causes the least significant digits to represent 0.0005 inch or
0.01 millimeter, depending on whether English or metric scale has been selected. Both X