1.3 TECHNICAL SPECIFICATIONS – check custom page to determine which

components apply to your CMS

1.3.1 Main Electronics (SCADA, RTU and HMI)

Input Power:

100-250 VAC, 50/60 Hz (UPS recommended)

Digital Communication:

TCP/IP:

Windows File Share (SMB)

OPC

Modbus

Web Interface

Wireless (optional)

All TCP/IP options are enabled by default

Serial:

RS-232 (Modbus) (optional)

Analog Communication:

4-20mA signals (optional)

Temperature Environment:

Operating: 40 to 120°F (5 to 49°C)

Storage: -20 to 158°F (-29 to 70°C)

Local Display (optional):

LCD Screen

or

2 x 20 alphanumeric LCD – displays output parameters and diagnostic messages

Parameter scrolling

Wireless Handheld Tablet (optional)

1.3.2 RheoVac Multi-Sensor Probe (MSP)

Typical Calibration Accuracy:

±5% of total mass flow

Repeatability:

±1.5% of reading

Operating Temperature:

Electronics: 40 to 120°F (5 to 49°C)

Probe: 40 to 158°F (5 to 70°C)

Never subject probe to temperatures above 210°F (99°C)

(high temperature protection optional, up to 450°F)

Operating Pressure:

0.5 to 10 inches Hg absolute

15 psia maximum

Storage Temperature:

-20 to 185°F (-29 to 85°C)

Storage Pressure:

15 psig (maximum)

Process Connection:

Ball valve assembly (1½" thread-o-let must be welded to pipe for installation)

Wetted Surface:

300 Series SS and engineered plastic (depending on model)