Controller and Display

CHS Series

32

2.6

Display Setup

Figure 2-32 Display Setup User Customizable Screen


Display Setup – menu screen, accessed by selecting
“Display Setup” from the “i-Information” screen,
allows the user to select which value (operating
parameter or sensor reading) is displayed on each of
the first 5 lines of the Home Screen. Use the up and
down (▲▼) buttons to navigate the menu options;
when the desired option is highlighted select by
pressing the “OK” button.

The comprehensive list of sensor I/O is identified in
Table 2-22 below.

Table 2-22 List of Optional Values for Display on Home/Summary Screen

Value

Description

System setpoint

Indicates the actual local CH setpoint (i.e. for a CH1 demand); adjusts for outdoor reset.

Operating temp

Indicates the temperature at the sensor used for burner modulation during a local CH or DHW
demand, i.e. boiler inlet, boiler outlet or system/pipe sensor.

Outlet temp

Indicates the temperature reading from the boiler outlet sensor.

Inlet temp

Indicates the temperature reading from the boiler inlet sensor.

Outdoor temp

Indicates the temperature reading from the outdoor sensor.

Delta T

Indicates the temperature difference between the boiler inlet and outlet sensors.

LL Operating temp

Indicates the temperature at the sensor used for burner modulation during a Lead Lag demand, i.e.
boiler outlet or system/pipe sensor.

LL System setpoint

Indicates the actual Lead Lag setpoint [i.e. for a CH2 (LL) demand]; adjusts for outdoor reset.

Fan speed

Indicates the speed that the combustion blower is running at – tachometer reading.

Flame signal

Indicates the flame current sensed from the flame probe.

Firing rate

Indicates the speed that the combustion blower is being commanded to operate at.

DHW temp

Indicates the dhw tank temperature (if used) or OPEN/CLOSED for Aquastat switch status.

Stack temp

Indicates the temperature reading from the boiler stack sensor.

4-20mA input

Indicates the input signal from an external 4-20mA source (used for direct burner modulation or
establishing temperature setpoint).

Lead Lag temp

Indicates the temperature reading from an optional system/pipe sensor.

LCD contrast

270

Home

screen

l

ine

1:

System

setpo

180

o

F

Home

screen

l

ine

2:

Operating

tem

71

o

F

Home

screen

l

ine

3:

Outlet

temp

71

o

F

Home

screen

l

ine

4:

I

nlet

temp

71

o

F

Home

screen

l

ine

5:

Outdoor

temp

OPEN

OS number

DSP49G2094

Software version

0.14