Operation when the arc boxes are grouped – Toa DP-K1 User Manual

Page 54

Advertising
background image

54

11.3. Operation When the ARC Boxes are Grouped

When the ARC boxes are grouped, the signal routing settings in the Zone assignment box are changed only
during ARC measurement, performing operation as follows.

The output channels assigned to the grouped ARC boxes are reassigned to the ARC box to be used for
measurement, and the measuring sound is output through this routing.

Note
Displays of the Zone assignment box and the Flow view remain unchanged.

[Setting example]
Below is an example of grouping [ARC 1] and [ARC 2] boxes.
For grouping setting, refer to

p. 56

.

• Signal flow in normal use

• Signal flow during measurement

Note: ARC boxes cannot be grouped between the different units.