REMOVING AND REPLACING NEEDLE
PLATE
• Raise needle to highest position and raise
presser foot.
-
1 Remove screws
screwdriver.
A and B using a large
Remove the needle plate by simply guiding it
toward you.
To replace needle plate, guide needle plate
into position under the presser foot. Replace
screws A and B using a large screwdriver
and tighten securely.
ATTACHING SNAP-IN FEED COVER
• Raise needle to highest position by turning
handwheel toward you.
• Raise presser foot.
• Slide snap-in feed cover away from you over
needle plate until points C and D are posi
tioned directly over holes in needle plate as
illustrated. Snap in point C. Then push point
D toward point C until it snaps into place.
Push down on point E until it also snaps into
place.
• To remove, lift up edges of feed cover.
ATTACHING THE SEAM GUIDE
Place screw in either hole to the right of the
needle plate; line up straight edge of guide with
the needle plate guideline for desired seam
width, and tighten screw.