Section 7,2- ENGINE DC CONTROL SYSTEM

Problem

4-

Engine Starts Hard and Runs Rough

TEST 15-CHECK

S P A R K .

TEST 16-CHECK

TEST 23- CHECK

NO

IGNITION SPARK

(with Spark Tester)

"" GOOD ^

SPARK PLUG

« GOOD^

CARBURETION

CHANGE

ENGINE MISS IS

APPARENT

SPARK PLUG BAD

ENGINE RUNS O.K. NOW

I

TEST 17-CHECK

IGNITION POWER

SUPPLY (WIRE 14)

i

iGOOD

1

CLEAN & REGAP

OR REPLACE

SPARK PLUG

STOP TESTS

INTERMITTENT

POWER SUPPLY

I

TEST 21-CHECK

ENGINE

CONTROLLER

BOARD OUTPUT

TO WIRE 14

BAD

TEST 18-CHECK

IGNITION

SENSOR

BAD

REPLACE

SENSOR

TEST 19- CHECK

IHMITinM

COIL

BAD

REPLACE COIL

f

REPAIR, RECONNECT

OR REPLACE BAD

TEST 20- TEST

WIRE(S) 14

AS REQUIRED

IGNITION MODULE

REPLACE ENGINE

^ CONTROLLER

CIRCUIT BOARD

I

BAD

1

REPLACE MODULE

TEST 22- TEST

TEST 24- CHECK

AUTOMATIC CHOKE — GOOD ►

ENGINE

BAD

i

ADJUST, REPAIR OR

REPLACE AS NECESSARY

REPAIR OR REPLACE

ENGINE AS NECESSARY

GOOD