Section 6.1- ENGINE DC CONTROL SYSTEM

CRANKING (CONT’D):

3. Engine Controller circuit board action operates

the automatic choke.

NOTE: Also see Section 3.5. “AUTOMA TIC CHOKE”

and Section 6.2, "ENGINE CONTROLLER BOARD”.

RUNNING:

With fuel flow and Ignition available, the engine

starts and runs. The operator releases the Start*

Run-Stop switch to its "RUN" position.

1. The Wire 18 circuit Is now open to ground. Circuit

board action terminates the 12 VDC to the Starter

Contactor (SC). The SC contacts open and crank­

ing ends.

2. Choking action ends and the carburetor choke

plate is positioned by the Choke Heater (CH).

3. Circuit board action continues to power the Wire

14 circuit- fuel flow and ignition continue.

How it Works (Continued)

NORMAL SHUTIDOWN:

When the Start-Run-Stop switch is held at

"STOP", the Wire 18 circuit Is connected to frame

ground. Engine Controller circuit board action

then terminates the DC flow to the Wire 14 circuit.

1. Fuel Pump (FP) shuts down.

2. Ignition terminates.
3. Engine shuts down.

NOTE: Connection of the circuit board’s Wire 18 or

Wire 18B circuit to frame ground will always result

In engine shutdown. Note that Wire 18B is routed

to the CCG circuit board, giving that circuit board

engine shutdown capability.

ENGINE PROTECTIVE DEVICE SHUTDOWN:

Refer to "Oil Filter Support" on Page 5.1-3 and

Section 6.5. The engine mounts a Low Oil Pressure

Switch (LOP) and a High Oil Temperature Switch.