Section 1.2- MAJOR GENERATOR COMPONENTS

The CCG

VOLTAGE CONTROL:

The CCG circuit board utilizes a closed-loop,

proportional-derivative

controller

which

regulates

RMS voltage by changing engine speed. The sys­

tem maintains output voltage at about 115 volts at
the lowest rpm and 120 volts up to the maximum
rpm.

The board controls a Stepper Motor (Figure 5),

which moves the throttle. The board calculates the
number of steps the Motor needs to take and sig­
nals the Motor to move. Motor movement changes

throttle position and changes In engine speed re­

sult.

FAULT PROTECTION:

Circuit Board (Continued)

CIRCUIT BOARD CONI

CONNECTIONS:

The board Is equipped with eight (8) connection

points

(receptacles).

These

are

identified

as

"CONNr through "CONNS". See Figure 9.

The CCG board has the ability to detect several

fault conditions and shut the engine down, as fol­

lows:
1. Overvoltage:- If the output voltage exceeds 127

VAC for longer than 15 seconds, the board will turn

AC output power off and shut the engine down.

2. Undervoitage:- If output remains below about 96
VAC longer than 15 seconds, an overload condition

probably exists. The board will then turn AC output

off and shut the engine down.

3. Overspeed:- if engine speed exceeds 4500 rpm,
shutdown will occur.
4. Failure of the Genistor (frequency converter) will

result in engine shutdown.

5. Loss of output to any circuit connected to the

board will result in engine shutdown.

CONNECTOR

FUNCTION

CONNI

Six-pin connector Interconnects

with speed control Stepper Motor.

CONN2

12-pin connector is NOT used on

RV units. An orange jumper wire

is connected across Pins 5 & 11.

CONN3

7-pin connector interconnects with

the Genistor.

CONN4

4-pln receptacle for connection of

the Stator power supply leads

(PS1, PS2) and the Stator timing

leads (TIM1, TIM2).

CONNS

Single point connection for Stator

lead No. 11 (blue).

CONN6

Interconnects with the Genistor.

CONN7

Single point connector Is NOT

used on RV units.

CONNS

Single point connector for Wire 18B.

Interconnects with Engine Cont­

roller circuit board, allows the

CCG board to shut the engine down.

Figure 9. the CÔà Circuit Board

0 0 ^

C0NN4

CDNN8 CDNN7

CDNN5

a

u

JSl_______________

CGNN3 CDNN6

lij Itl lil Ui lli'ururuu umuuiuiuniniimui Ui'Ul uul

Ì

i

o

m f a m f s i f s i f i i f g i f a i f g i m f i i m f s i m m i s i f C T m i j u n j

-O

■~L0r'

o

Page 1.2-4