The genistor, The ccg circuit board – Generac Power Systems NP-40G User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Section 1.2- MAJOR GENERATOR COMPONENTS

The Genistor

GENERAL:

See Figure 6. The GENISTOR is often called a

“frequency converter“ (also see "Introduction to
CCG’s“ on Page 1.1-4). its function is to change the
high frequency AC output of the Stator (336-540
Hertz) to a useful frequency (about 56-60 Hertz).

The Genistor has no intelligence of Its own. It is

simply a high speed switcning device which is
controlled by the CCG circuit board.

Figure 6. The dtenhtor

GENISTOR THEORY:

The purpose of a “frequency converter“ is to

divide the Stator AC output frequency by an inte­
gral factor to provide a useful output frequency.

Each of the four half-phases of the center-tapped

Stator Is Genistor-controlled.

Figure 7 shows the sine wave output from the

2-phase Stator windings. This output Is delivered

to the Genistor switching module.

Switching signals from the CCG circuit board are

also

delivered

to

the

Genistor.

These

signals

switch the Genistor on and off as required, result­

ing In a sine wave output to the load as shown in

Figure 8.

The CCG Circuit Board

GENERAL:

The CCG circuit board has several functions as

follows:

1. It controls the operation of the “frequency con­

verter“ (Genistor).

2.

It controls AC output voltage under all load

requirements by controlling engine speed.
3. It protects the system against various faults.

FREQUENCY CONTROL:

The CCG board will adjust the number of alterna­

tor cycles In one output cycle to control AC output

frequency. The number of cycles is based on en­

gine rpm and the output frequency will be main­

tained in the 55-65 Hertz band.

The board uses a "zero crossing" detector to

synchronize an internal clock. The frequency of the
Stator’s

waveform

is

measured

and,

with

referencve to the required output frequency, a “fre-

guency divisor" is calculated. The circuit board

then signals the Genistor (frequency converter) to

switch on and off at the proper times so that fre­
quency Is maintained in the 55-65 Hertz band.

Page 1.2-3