Section 3.3- FILTER & FUEL PUMP

Fuel Filter

The fuel filter should be removed end replaced every

100 hours of operation or once each year, whichever

occurs first

The 12 voKs DC electric fuel pump has a zinc plate

finish. Flow through the pump Is positively shut off

when it is not operating. The pump Is actually rated at a

voltage of 8 to 16 VDC, but has a nominal voltage rating

of 12 VDC.

Current draw of the pump at nominal voltage Is ap­

proximately 1.4 amperes maximum.

Pressure rating of the pump at zero delivery is 2.0 to

3.5 psi.

Two wires are brought out from the pump. The black

wire Is grounded by connecting It to a pump mounting

bolt The red wire is Identified as Wire No. 14A. The pump

will operate whenever:

□ The FUEL PRIME switch on the generator panel is

actuated to Its "ON” position.

□ During engine startup and running conditions when

the Engine Controller circuit board energizes the

Wire No. 14 circuit

TESTING THE PUMP:

1. The pump coll can be tested for an open or shorted

condition as follows:

a. Test for "Open":

(1)

Disconnect the RED pump wire at Its "bullet* lug.

(2) Set a VOM to Its *Rx1" scale and zero the meter.

(3) Connect one meter test probe to the RED pump

wire, the other test probe to terminal end of the

pump’s BLACK lead. The VOM should Indicate

pump coll resistance.

FUEL PUMP NOMINAL COIL RESISTANCE

ABOUT 0.75 to 1.00 ohm

b. Test for "Shorted" condition:

(1) Disconnect the RED and the BLACK fuel pump

leads.

(2) Set a VOM to its "Rxl0,000" or "RxlK" scale and

zero the meter.

(3) Connect one VOM test lead to the pump RED

lead, the other test probe to the pump body. The

meter should read "Infinity".

2. Pump operation can be tested as follows:

a. Disconnect the fuel line from the outlet side of the

fuel pump.

b. Make sure a supply of fuel Is available to the inlet

side of the pump.

c. The RED lead from the pump must be connected

properly Into the circuit The pump’s BLACK lead must

be connected at the pump mounting bolt

d. Actuate the Fuel Prime switch on the generator

panel. The pump should operate and should pump fuel

from the outlet side.

NOTE: If desired, a pressure aauge can be attached
to the pump’s outlet side. Pump outlet pressure

should be 2.0 to 3.5psI.

Page 3.3-1