Section 7.2- ENGINE DC CONTROL SYSTEM

Test 1- Check 15 Amp Fuse

DISCUSSION:

The panel-mounted 15 amp fuse Is connected In

series with the 12 VDC power supply to the engine

DC control system. A blown fuse will prevent en­

gine priming, cranking and running.

TEST PROCEDURE:

Push in on fuse holder cap

and turn it counterclockwise to

remove cap and fuse. Check

the fuse visually. If the fuse

metal element has melted

open, replace the fuse.

If the visual check is uncer­

tain, use a VOM to check fuse.

RESULTS:
1. If fuse is good

a. And if priming function does not work, go to

Test 2.

b. And if engine will not crank, go to Step 4.

2. If fuse is bad, replace it

Test 3- Check Power to Fuel Pump

DISCUSSION:

When the rocker type primer switch Is held at

ON", position, fused battery voltage Is delivered to

the electric fuel pump. The pump should then turn

on and prime the carburetor.

During cranking and startup, the engine control­

ler circuit board will deliver battery voltage to the

Wire 14 circuit and to the Fuel Pump. The pump

should turn on and run.

TEST PROCEDURE:

Locate the red Wire 14A that connects to the fuel

pump. A wiring connector connects the wires near

the pump. Separate the wire, then check for DC

power as follows:

1. Set VOM to read battery voltage.

2. Connect the VOM test leads across the Wire 14A

from the Primer Switch and frame ground.
3. Hold the Primer Switch at “ON" (Prime). Meter

should read battery voltage.
4.

Hold the panel Start-Run-Stop switch at

“START". The meter should read battery voltage.

Test 2- Check Power to Switch

DISCUSSION:

This is a check of the PRIMER SWITCH on the

panel. When the switch is actuated to its “PRIME"

position, fused battery voltage is delivered directly

to the electric fuel pump on units with gasoline fuel

system. On units with gaseous fuel system, battery

voltage is delivered to the fuel lockoff solenoid.

TEST PROCEDURE:

Set a VOM to read battery voltage (12 VDC).

Connect the meter test leads across the Wire 15

terminal of the Primer Switch and frame ground.

The meter should read battery voltage.

RESULTS:

1. if battery voltage is Indicated, go to Test 3.

2. If battery voltage is NOT Indicated, go to Test 4.

RESULTS:

1. If unit is being tested because the priming func­

tion doesn’t work:

a. If battery voltage is good but the pump doesn’t

work, go to Test 5.

b. If battery voltage is NOT indicated, go to Test

6.

2. If engine cranks but will not start:

a. if battery voltage is good but pump doesn’t

work, go to Test 5.

b. If DC power to pump Is good and pump works,

go to Test 22.