Section 1.5- COMPONENTS TESTING

TESTING THE CIRCUIT BOARD;

There Is no practical way of testing the CCG

circuit board In the field. Read "SYMPTOMS OF
CIRCUIT BOARD FAILURE" carefully. Test the Sta­

tor, the Genistor, and the Battery Charge circuit as

outlined In this Section. Also perform a resistance

test of the Stepper Motor (see Part 7, "THE VARI­

ABLE SPEED SYSTEM") and observe Its operation

If possible.

Inspect wiring and wiring connections between

the CCG circuit board and the Genistor as follows

(refer to appropriate wiring diagram):

1. Check wires G1 through G4 (and Wire 22) for

proper connections at circuit board and at the

Genistor.
2. Use a VOM to check Wires G1 through G4 (and

Wire 22) for continuity.
3. Check Wires AC1, AC2, SL1 and SL2 (between

circuit board and Genistor) for proper connections.
4. Use a VOM to check Wires AC1, AC2, SL1, SL2

(between circuit board and Genistor) for condlnu-

Ity.

If all tests are completed and no problem Is found

on other components of the system, replace the

CCG circuit board and check unit operation.