Nespresso Citiz & Co  EF 488 User Manual

Page 106

Advertising
background image

Citiz service manual 

106 

R E P A I R S 

Assembly checkpoints ­ fine wire fuse(s) 

• 

When mounting a safety clip (a) on the thermoblock (15), make sure that the housing 
of the fine wire fuse (b) is positioned exactly below the safety clip. 

• 

Tighten fastening screw and spring ring with a torque wrench (150 (+30/­0) Ncm). 

Assembly checkpoints ­ thermoblock 

• 

All wires from thermoblock to platform must be led through the bracket (a) at the 
bottom of the support. 

• 

The black grommets (b) on the electrical thermoblock connections are slitted at the 
end. If an angled Faston receptacle (c) is used, make sure that its wire runs through 
this slit. 

• 

Tighten central fastening screw (d) with a torque wrench (150 (+30/­0) Ncm).

Advertising