1 preparations – Nespresso Citiz & Co  EF 488 User Manual

Page 134

Advertising
background image

Citiz service manual 

134 

F U N C T I O N   T E S T S 

9.4.1  Preparations 

Depending on core 
unit range, refer to 
"Disassembly of core 

unit, C­range" on page 91 
or "Disassembly of core 
unit, D­range" on page 109. 

The pressure adapter 
must sit firmly in the 
capsule bay. 

1)  Remove left side panel of core unit. 
2)  Insert core unit back into platform. 
3)  Fill and insert water tank. 

4)  Insert connecting unit of pressure 

adapter into capsule bay. Push back 
sealing cone into capsule cage. 

5)  Insert fixation unit of pressure adapter 

into capsule bay. 

6)  Press down operating lever. 
7)  Connect pressure hose to pressure 

tester. 

8)  Place a measuring cup under the drain 

hose of the pressure tester.

Advertising