8.4.4  Replacing power cord 

• 

Remove water tank connector from platform first (see page 59). 

• 

Remove insulated faston receptacle of phase wire from mains switch (54). 

• 

Disconnect adapter plug of neutral wire (15). 

• 

If present, disconnect ground wire (15, see detail). 

• 

Unlatch cable bracket (56) with screwdriver. 

The hoses can 
remain on the water 
tank connector. 

Use a pair of flat pli­ 
ers to pull off insulat­ 
ing sleeve with recep­ 

tacle. 

The flat receptacle on 
the ground wire has a 
special connector 

latching (see detail). Press 
down lever at first, then pull 
off receptacle. 

The cable bracket is 
under tension. There­ 
fore, hold the cable 

bracket with your finger 
when unlatching it.