8.5.5  Replacing power cord 

• 

Remove 2 insulated faston receptacles (55) from mains switch (54). 

• 

If present, disconnect ground wire (15, part of thermoblock assembly). 

• 

Unlatch cable bracket (56) with screwdriver. 

Use a pair of flat pli­ 
ers to pull off insulat­ 
ing sleeve with recep­ 

tacle. 

The counterpart, a 
flat receptacle, has a 
special connector 

latching (see detail). Press 
down lever at first, then pull 
off receptacle. 

The cable bracket is 
under tension. There­ 
fore, hold the cable 

bracket with your finger 
when unlatching it.