3 test sequence – Nespresso Citiz & Co  EF 488 User Manual

Page 145

Advertising
background image

Citiz service manual 

145 

F U N C T I O N   T E S T S 

9.9.3  Test sequence 

Danger of electrical shock/short circuit! 
Do not plug in the coffee machine during insulation test. 

Danger of electrical shock! 
Do not touch tip of test probes. 
Do not touch metallic parts of coffee machine during test. 
Read and observe safety instructions in user manual of test equipment. 

A Swiss power plug is 
shown here as an 
example. 

Use a short circuit 
plug or special alliga­ 
tor clips etc. as sub­ 

stitute for this test adapter. 

1)  Connect the phase and neutral pin of 

the power plug together with a test 
adapter (procured by the repair 
centre). 

2)  Connect the black measuring cable to 

the test adapter (see image). 

3)  Turn the ON­OFF machine's main 

switch on position I (ON). 

Symbolic illustration 
of test equipment. 

4)  Switch on test equipment and select 

an insulation test voltage of 500 V DC. 

Some test equipment 
displays test passed 
or failed instead of 

the insulation resistance. 

5)  Touch closing handle with red test 

probe. 

6)  Press "measure" button. 
7)  Read off displayed insulation resist­ 

ance or test result. 

The insulation resistance must be 
higher than 300 kOhm 
(300,000 Ohm).