F U N C T I O N   T E S T S 

9.3  Measure flow rate 

The pressure adapter 
must sit firmly in the 
capsule bay. 

1)  Fill and insert water tank. 
2)  Open closing handle. 

3)  Insert connecting unit of pressure 

adapter into capsule bay. Push back 
sealing cone into capsule cage. 

4)  Insert fixation unit of pressure adapter 

into capsule bay. 

5)  Press down operating lever. 
6)  Connect pressure hose to pressure 

tester. 

7)  Place a measuring cup under the drain 

hose of the pressure tester.