F U N C T I O N   T E S T S 

9.8.3  Test sequence 

This test sequence is 
not applicable for cof­ 
fee machines with 

two­wire power cords (with­ 
out ground pin). 

Danger of electrocution! 
Do not plug in the coffee machine during the protective earth continuity 
test. 
Read and observe safety instructions in user manual of test equipment. 

1)  Connect black measuring cable to 

ground pin of power plug with an alli­ 
gator clip (example shown: Swiss 
power plug). 

Symbolic illustration 
of test equipment. 

2)  Switch on test equipment and select 

protective earth continuity test. 

The coffee machine 
Citiz & Co has 2 test 
holes to check both 

thermoblocks. 

Test holes on bottom of Citiz / Citiz & milk / Citiz & Co  platforms 

3)  Insert tip of red test probe in test hole 

and touch thermoblock. 

4)  Press "measure" button and read off 

displayed resistance. 

The resistance must be lower than 
0.3 Ohm. 

5)  Fill in measured value(s) in a test 

report.