Citiz service manual
107
R E P A I R S
8.7.7 Replacing electronic control board with button prints
•
Remove at first
NTC connector from electronic control board,
connector cable from flow meter,
electronic lid (43),
faston receptacles from electronic control board.
•
Insert tip of screwdriver between chassis (1) and protective case of electronic control
board (42) to release latches. Then pull out assembly.
The replacement
board is equipped
with protective hous
ing and cover.