Citiz service manual 

G E N E R A L   S A F E T Y   N O T E S 

G E N E R A L   S A F E T Y   N O T E S 

As an additional safety measure, the use of a residual current device (RCD), also called 
the ground fault circuit interrupter (GFCI), in the repair centre is highly recommended. 

Risk of fatal electrical shock and fire! 

Mains voltage inside the coffee machine. 

• 

Unplug appliance before cleaning. 

• 

Never clean wet or immerse plug, cord or appliance in any fluid. 

• 

Disconnect the mains plug before disassembly ­ the appliance must 
be free of voltage. 

This device does 
not protect against 
electrical shock due 

to contact with both cir­ 
cuit conductors. 

Example illustrations 
of typical devices. 

Use a GFCI with a trip 
level of 4 ­ 6 mA (USA) 
resp. a RCD with a trip 

level of 15 ­ 30 mA (Europe). 
A trip level above 30 mA 
provides only very limited 
protection against harm 
from an electric shock. 

1)  RCD protected socket­outlet 
2)  Plug­in RCD unit 

3)  GFCI socket 
4)  Plug­in GFCI 

Danger of burns! 

Hot parts and water under pressure inside the coffee machine 
(particularly in the thermoblock). 

• 

Let coffee machine cool down before cleaning or disassembly.