Designation of spare parts, Electrostatic discharge protection, Wiring arrangement – Nespresso Citiz & Co  EF 488 User Manual

Page 54: Residual water

Advertising
background image

Citiz service manual 

54 

R E P A I R S 

Designation of spare parts 

The components in the following illustrations are indexed with position numbers. 
See separate spare parts list for corresponding spare part numbers. 

Distinguish between spare parts of the different models and core unit 
versions. 

Electrostatic discharge protection 

When installing a new electronic control board, the service technician must be earthed 
with a grounding band. 

Wiring arrangement 

Random changes in the wiring arrangement during a repair can cause 

­ 

electromagnetic interferences, 

­ 

squeezed wires, 

­ 

insulation defects due to contact with hot parts, 

­ 

insulation problems if low and high voltage wires are not separated. 

Protective measures: 

• 

Do not change the course of internal wiring during repair. 

• 

Make sure that wires are distant from hot parts ­ use existing cable ducts and clips. 

Residual water 

• 

If it is necessary to pull off hoses from components, hold ready a small beaker and 
a towel to collect and wipe away leaking water. 

• 

A special procedure is necessary to empty the fluid system of the coffee machine for 
repair or shipment (refer to "Empty water system" on page 37). 

TX 20 screw / 
ground connection (PE) on ther­ 
moblock 

150 (+30/­0) Ncm 

1.5 (+0.3/­0) Nm 

Screw / screw connection 

Torque 

Position