R E P A I R S
•
If present, disconnect ground wire (15, part of thermoblock assembly).
•
If the thermoblock or core unit has to be replaced, disconnect milk frother connector
(57). Otherwise the core unit can be removed together with this connector (see page
73).
•
Remove water tank connector (53, see page 71).
Assembly checkpoints
•
All covers are assembled on the core unit.
•
Check that wiring between core unit and platform is led through cable fixation (71).
•
Use marked cable guides to lay wires.
•
Check wiring of milk frother connector (57), see detail.
•
Check wiring of mains switch (54), see "Wiring diagrams model Citiz & milk,
EF 485/486" on page 124 and following.
•
During assembly of the water tank connector (53) on the platform, each of its 3
latches has to engage with an audible click.
The flat receptacle on
the ground wire has a
special connector
latching (see detail). Press
down lever at first, then pull
off receptacle.