2.7 Clock Source Setting

The programmable interval timer 8254 is used in the PCI-9112. It provides 3
independent 16-bit programmable down counters. The input to counter 2 is
connected to a precision 2MHz oscillator for the internal pacer. The input of
counter 1 is cascaded from the output of counter 2. Channel 0 is free for
user applications. There are two selections for the clock source of channel 0:
the internal 2MHz clock or an external clock signal from connector CN3 pin
35. The setting for clock source is shown as Figure 2.5.

Internal Clock

Source: 2MHz

(default setting)

External Clock

Source

JP2

JP2

INTCLK

EXTCLK

INTCLK

EXTCLK

Figure 2.5 Timer's Clock Source Setting

2.8 D/A Reference Voltage Setting

The D/A converter's reference voltage source can be supplied both internally
and external
. The external reference voltage comes from connector CN3 pin
31 (ExtRef1) and pin12 (ExtRef2), see section 3.1. The reference source of
the D/A channel 1 and channel 2 are selected by JP4, respectively. The
possible settings are shown below: