ADLINK PCM-9112+ User Manual

Page 26

Advertising
background image

18

Installation

D/A CH1 is External

D/A CH2 is External

JP4(PCI-9112, cPCI-9112R)

JP5(cPCI-9112)

INTREF

ExtRef2

ExtRef1

INTREF

D/A CH1 is Internal

D/A CH2 is Internal

(default setting)

D/A CH1 is Internal

D/A CH2 is External

D/A CH1 is External

D/A CH2 is Internal

INTREF

ExtRef2

ExtRef1

INTREF

INTREF

ExtRef2

ExtRef1

INTREF

INTREF

ExtRef2

ExtRef1

INTREF

Figure 2.6 Analog Output Voltage Setting

The internal D/A reference voltage can be set to –5V or –10V by JP3. The
possible configurations are specified as Figure 2.7. Note that the internal
reference voltage is used only when the JP4 is set to internal reference only.

R eference Voltage is

-5V (default setting)

J P 3

-10V

-5V

J P 3

-10V

-5V

R eference Voltage is

-10V

Figure 2.7 Internal Reference Voltage Setting

Note: If the -10V D/A reference voltage is selected, the D/A output range is

0V~10V. On the other hand, if the -5V is selected, the D/A output
range is 0V~5V.

Advertising